Identifies the provider related circuit ID to which traffic is to be routed or the facility being disconnected.
NOTE 1: When alternate routing is ordered, then the first RECCKT field, the second RECCKT field and the REMARKS field are populated to specify the ID of the related circuits.
NOTE 2: The first RECCKT field corresponds to the first SCRT entry.
NOTE 3: Use the REMARKS field for specifying more than two such circuit groups.
NOTE 4: When adding capacity to an existing group(s) or ordering a change in the trunking arrangement, this field should be populated.
NOTE 5: This field would not be populated when the circuit IDs have not been assigned for the alternate group.
NOTE 6: When the facility associated with trunks is also being disconnected, this field should be populated with the facility identification.
The format of the field is defined by the provider.
All components within the ID should be delimited by either virgules or periods.
The layout of the field is defined by the COMMON LANGUAGE standards.
When a component of Circuit ID information is purposely omitted, the component should still be delimited and compressed to eliminate any spaces.
If all positions in a component of circuit ID information are not populated, the component should be compressed to eliminate any spaces.
Ranges should be shown within the appropriate component of the ID by specifying the lowest value of the component, hyphen, highest value of the component, e.g., trunk numbers 3500 through 3512 would be shown as 3500-3512.
If the customer wishes to disconnect all circuits in a given account, they enter the billing account number in the BAN field and "ALL" in this field and a "D" in the ACT field.
Use of ranging is based on customer/provider negotiations.
USAGE: This field is conditional.
NOTE 1: Required when disconnecting facilities and the ACT field on the ASR Form is "D".
NOTE 2: Optional when the ACT field on the ASR Form is "N" or "C" and alternate routing is ordered or the SCRT field is populated.
NOTE 3: Otherwise prohibited.
DATA CHARACTERISTICS: 53 alpha/numeric characters
EXAMPLES: W 0 1 1 2 / T 6 7 8 9 0 / M I L W W I A U W 0 1 /
M I L W W I 1 3 C G 0
1 2 3 4 / A F 5 4 I E C N / M D S N W I 1 6 C G 0
/ M - / M D S N W I 0 2 0 1 T
NOTE 1: These examples indicate a single facility.
W 0 2 2 1 , W 0 2 2 5 , W 0 2 2 7 / T 6 7 8 9 0 /
M I L W W I A U W 0 1 / M I L W W I 1 3 C G 0
1 0 1 , 1 0 5 , 1 0 7 , 1 0 9 / T 6 7 8 9 0 / N W
R K N J A U W 0 1 / N W R K N J 1 5 D S 0
NOTE 1: These examples indicate multiple facilities-series entry.
W 0 1 0 1 - W 0 1 2 7 / T 6 7 8 9 0 / M I L W W
A U W 0 1 / M I L W W I 1 3 C G 0
NOTE 1: This example indicates multiple facilities-range entry.