SECLOC - Secondary Location

Identifies the terminating end of the circuit, a provider central office or the first point of switching for the circuit being provided.

NOTE 1: When the entry in this field contains a CLLI Code, the format and structure of this field is defined in the ANSI approved standard, ATIS-0325300, Identification of Location Entities for the North American Telecommunications System or by COMMON LANGUAGE in BR-795-402-100. A brief summary of the format can be found in ATIS-0404000 Section 2.14.1.

NOTE 2: When the SECLOC is an end user premises, the SECLOC field must be populated with an “E” and the end user name will be populated in the EUNAME field on the SALI Form that will be provided when necessary.  When an “E” is entered in this field and the CLLI Code has been pre-assigned, then the CLLI Code should be entered in the SPOT field on the SALI Form.

NOTE 3: When the SECLOC termination is an unbundled transport network element at a second ACTL, the SECLOC field may be populated with a “C” followed by the CLLI code of the secondary ACTL.

NOTE 4: SECLOC is not populated when requesting a multipoint configuration. CKLT is used to specify the first bridging location and an MSL Form is used for specifying end user and/or additional bridge terminations. The MSL Form must accompany the Transport Form when ordering multipoint configurations.

NOTE 5: SECLOC is a CLLI Code when ordering facilities to a provider end office. This code must be preceded with a “C”. This can also be a secondary ACTL CLLI Code.

NOTE 6: SECLOC may be populated with a CLLI Code or left blank when ordering facilities to a provider broadband switch. When this field is left blank, the provider will determine the switch location and provide the switch CLLI Code on the Confirmation Notice Form (CN).

NOTE 7: The following describes the use of the SECLOC field when ordering a High Capacity facility and in ordering the utilization of the High Capacity facility.

• The High Capacity facility is ordered between an ACTL and a HUB. The HUB would be specified in CLLI Code format in the SECLOC field.

• A subsequent request for a two point special access facility utilizing capacity in the previously provided High Capacity facility would be ordered as follows:

 The SECLOC field would be “E” followed by blanks.

 The EUNAME field on the SALI Form would specify the end user name at the premises where the circuit terminates.

 The CFA field would specify the particular channel in the High Capacity facility to be utilized to provide the two point special access service. The CFA (Connecting Facility Assignment) is provided to the customer in the provisioning of the High Capacity facility.  The customer then specifies the particular High Capacity facility and the channel assignments utilizing the CFA field.

• A subsequent request for a multipoint special access  facility utilizing capacity in the previously provided High Capacity facility would be ordered as follows:

 The SECLOC field would be left blank and the end user location(s) are ordered using the MSL and SALI Forms that will be provided when necessary.

 The CKLT field would specify the Bridge location.

 The CFA field requirement is the same as previously stated.

 The NSL field would specify the quantity of secondary locations with circuit activity.

• A subsequent request for a thru-connect utilizing capacity in the previously provided High Capacity facility would be ordered as follows:

 The SECLOC field should be populated with an “E” and the end user name will be populated in the EUNAME field on the SALI Form that will be provided when necessary, or a “C” followed by the CLLI Code of the secondary ACTL.

 The CFA field would specify the particular channel in the High Capacity facility to be utilized toward the ACTL.

 The SCFA would specify the particular channel in the High Capacity facility to be utilized toward the secondary ACTL.

• A subsequent request for a connection to a collocation node (secondary ACTL) utilizing capacity in the previously provided High Capacity facility would be ordered as follows:

 The SECLOC field should be populated with a “C” followed by the CLLI Code of the secondary ACTL.

 The CFA field would specify the particular channel in the High Capacity facility/unbundled multiplexer to be utilized toward the ACTL.

 The SCCEA field may identify the tie-down assignment at the SECLOC (secondary ACTL).

VALID ENTRIES:

PREFIX

FOLLOWED BY

DESCRIPTION

E

Blanks Used if SECLOC is an end user’s premises (for special access terminations).

C

CLLI Code Used if SECLOC is a provider end office termination (including CENTREX) or a secondary ACTL when termination is UNE transport.

 

NOTE 1: Valid CLLI Codes are maintained by Telcordia Technologies.

NOTE 2: When the valid entry is “E” and the NAG field on the ASR Form is not populated, the SALI Form is required.

NOTE 3: When the valid entry is “E” and the NAG field on the ASR Form is populated, the SALI Form is prohibited.

NOTE 4: When the valid entry is “C” followed by a CLLI Code, the SALI Form is prohibited.

USAGE: This field is conditional.

NOTE 1: Required when the first position of the REQTYP field on the ASR Form is “S”, the ACT field on the ASR Form is “N”, “C”, “M” or “T”, and NSL field is not populated.

NOTE 2: Prohibited when the NSL field is populated.

NOTE 3: Otherwise optional.

DATA CHARACTERISTICS: 12 alpha/numeric characters

EXAMPLES: C M I L N T N M A 6 8 6

                       E

   C B S T N M A F R H P A