Identifies the provider end office providing the FGA switched access services.
NOTE 1: The format and structure of this field is defined in the ANSI approved standard, ATIS-0325300, Identification of Location Entities for Information Exchange or by COMMON LANGUAGE in BR-795-402-100. A brief summary of the format can be found in ASOG Practice 000, Section 2.14.1.
NOTE 2: The following describes the use of the SECLOC field when a FGA service and an extension off the FGA are ordered all within a particular LATA .
1. Four (4) request forms are required.
· ASR Form
· FGA Form
· MSL Form(s) (for ordering the FGA extension)
· SALI Form(s) (for ordering the FGA extension)
2. The FGA Form should contain the following:
· SECLOC = Central Office Location (CLLI Code)
· D-TEL = Customer option for identification of telephone number and or serving office.
· NSL = The number of extensions off the FGA main service which will equal the quantity of associated MSL/forms.
· GETO = IntraLATA Extension Coded Entry
3. The MSL Form would contain the following:
· SECLOC = āEā, indicating that the SECLOC termination is an end user location for the FGA extension service off the main service location.
4. The SALI Form (s) would contain the following:
· EUNAME = End user name for the FGA extensions that terminate at an end user.
NOTE 3: When an extension terminates in a LATA other than the FGA main service LATA, the customer would order the extension using the Special Access order form and placing it with the appropriate provider location. The MSL SECLOC would indicate the customer location from which the circuit is hauled out of the LATA providing the main service.
VALID ENTRIES:
11 character CLLI Code
NOTE 1: Valid CLLI Codes are maintained by Telcordia Technologies.
USAGE: This field is conditional.
NOTE 1: Required when the ACT field on the ASR Form is "N", otherwise optional.
DATA CHARACTERISTICS: 11 alpha/numeric characters
EXAMPLE: M I L N T N M A 6 8 6