DIR1 - Directionality

Identifies the direction of the circuit's path when it ingresses (enters) on a bi-directional dedicated or bi-directional Dense Wave Division Multiplexing Ring identified in the PRI ADM field and the customer has assignment control.

VALID ENTRIES:

1 = High speed group side one

2 = High speed group side two

3 = High speed group side one and two-simultaneous

NOTE 1: The definition of side 1 and side 2 valid entries is based on customer and provider negotiations.

NOTE 2: An entry of “3” is only valid when the FNT field on the ASR Form is “B”.

USAGE: This field is conditional.

NOTE 1: Optional when the PRI ADM field is populated.

NOTE 2: Optional when the CFA field is populated.

NOTE 3: Optional when the PRI ADM and CFA fields are populated.

NOTE 4: Otherwise prohibited.

DATA CHARACTERISTICS: 1 numeric character

EXAMPLE: 1